FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.medizininformatikinitiative.kerndatensatz.icu#2024.0.0-alpha2 (79 ms)

Package de.medizininformatikinitiative.kerndatensatz.icu
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2024.0.0-alpha2&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-extrakorporalen-verfahren
Url https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-extrakorporalen-verfahren
Version 1.0.0
Status active
Name SD_MII_ICU_Parameter_Von_Extrakorporalen_Verfahren
Title SD MII ICU Parameter von Extrakorporalen Verfahren
Experimental False
Type Observation
Kind resource

Resources that use this resource

StructureDefinition
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/arterieller-druck SD MII ICU Arterieller Druck
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/blutfluss-cardiovasculaeres-geraet SD MII ICU Blutfluss Cardiovasculaeres Geraet
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/blutfluss-extrakorporaler-gasaustausch SD MII ICU Blutfluss Extrakorporaler Gasaustausch
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/blutflussindex-extrakorporaler-gasaustausch SD MII ICU Blutflussindex Extrakorporaler Gasaustausch
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/dauer-extrakorporaler-gasaustausch SD MII ICU Dauer Extrakorporaler Gasaustausch
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/dauer-haemodialysesitzung SD MII ICU Dauer Haemodialysesitzung
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/haemodialyse-blutfluss SD MII ICU Haemodialyse Blutfluss
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/ionisiertes-kalzium-nierenersatzverfahren SD MII ICU Ionisiertes Kalzium Nierenersatzverfahren
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/sauerstoffgasfluss SD MII ICU Sauerstoffgasfluss
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/substituatfluss SD MII ICU Substituatfluss
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/substituatvolumen SD MII ICU Substituatvolumen
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/venoeser-druck SD MII ICU Venoeser Druck

Resources that this resource uses

StructureDefinition
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/devicemetric-eingestellte-gemessene-parameter-extrakorporale-verfahren SD MII ICU DeviceMetric Eingestellte Gemessene Parameter Extrakorporale Verfahren
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/extrakorporales-verfahren SD MII ICU Extrakorporales Verfahren
https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference MII-Reference
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/BodySite-Observation-extrakorporale-Verfahren VS MII ICU BodySite Observation extrakorporale Verfahren
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/code-observation-extrakorporale-verfahren-iso11073 VS MII ICU Code Observation extrakorporale Verfahren [ISO11073]
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-extrakorporale-Verfahren-LOINC VS MII ICU Code Observation extrakorporale Verfahren [LOINC]
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-extrakorporale-Verfahren-SNOMED VS MII ICU Code Observation extrakorporale Verfahren [SNOMED]


Narrative

Note: links and images are rebased to the (stated) source

No human-readable text provided in this case.

Source

{
  "resourceType" : "StructureDefinition",
  "id" : "sd-mii-icu-parameter-von-extrakorporalen-verfahren",
  "text" : {
    "status" : "empty",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">No human-readable text provided in this case.</div>"
  },
  "url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-extrakorporalen-verfahren",
  "version" : "1.0.0",
  "name" : "SD_MII_ICU_Parameter_Von_Extrakorporalen_Verfahren",
  "title" : "SD MII ICU Parameter von Extrakorporalen Verfahren",
  "status" : "active",
  "contact" : [
    {
      "name" : "Müller, Christoph",
      "telecom" : [
        {
          "system" : "email",
          "value" : "christmueller@ukaachen.de"
        }
      ]
    }
  ],
  "fhirVersion" : "4.0.1",
  "mapping" : [
    {
      "identity" : "workflow",
      "uri" : "http://hl7.org/fhir/workflow",
      "name" : "Workflow Pattern"
    },
    {
      "identity" : "sct-concept",
      "uri" : "http://snomed.info/conceptdomain",
      "name" : "SNOMED CT Concept Domain Binding"
    },
    {
      "identity" : "v2",
      "uri" : "http://hl7.org/v2",
      "name" : "HL7 v2 Mapping"
    },
    {
      "identity" : "rim",
      "uri" : "http://hl7.org/v3",
      "name" : "RIM Mapping"
    },
    {
      "identity" : "w5",
      "uri" : "http://hl7.org/fhir/fivews",
      "name" : "FiveWs Pattern Mapping"
    },
    {
      "identity" : "sct-attr",
      "uri" : "http://snomed.org/attributebinding",
      "name" : "SNOMED CT Attribute Binding"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Observation",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation",
        "path" : "Observation",
        "constraint" : [
          {
            "key" : "obs-10",
            "severity" : "error",
            "human" : "Either subject XOR encounter exists",
            "expression" : "$this.encounter.exists() xor $this.subject.exists()",
            "source" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-extrakorporalen-verfahren"
          },
          {
            "key" : "vs-de-2",
            "severity" : "error",
            "human" : "If there is no component or hasMember element then either a value[x] or a data absent reason must be present",
            "expression" : "(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())",
            "source" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-extrakorporalen-verfahren"
          }
        ]
      },
      {
        "id" : "Observation.identifier",
        "path" : "Observation.identifier",
        "mustSupport" : true
      },
      {
        "id" : "Observation.partOf",
        "path" : "Observation.partOf",
        "short" : "Observation belongs to a specific extracorporeal procedure.",
        "definition" : "Dasjenige extrakorporale Verfahren, im Rahmen dessen der vorliegende Parameter (die Daten dieser Observation-Ressource) erhoben wurden.",
        "min" : 1,
        "max" : "1",
        "type" : [
          {
            "code" : "Reference",
            "profile" : [
              "https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
            ],
            "targetProfile" : [
              "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/extrakorporales-verfahren"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.status",
        "path" : "Observation.status",
        "mustSupport" : true
      },
      {
        "id" : "Observation.category",
        "path" : "Observation.category",
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Observation.category.coding",
        "path" : "Observation.category.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "closed"
        },
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Observation.category.coding:sct",
        "path" : "Observation.category.coding",
        "sliceName" : "sct",
        "patternCoding" : {
          "system" : "http://snomed.info/sct",
          "code" : "182744004"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.category.coding:sct.system",
        "path" : "Observation.category.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.category.coding:sct.code",
        "path" : "Observation.category.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.category.coding:sct.display",
        "path" : "Observation.category.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code",
        "path" : "Observation.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding",
        "path" : "Observation.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "closed"
        },
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:sct",
        "path" : "Observation.code.coding",
        "sliceName" : "sct",
        "patternCoding" : {
          "system" : "http://snomed.info/sct"
        },
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-extrakorporale-Verfahren-SNOMED"
        }
      },
      {
        "id" : "Observation.code.coding:sct.system",
        "path" : "Observation.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:sct.code",
        "path" : "Observation.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:sct.display",
        "path" : "Observation.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc",
        "path" : "Observation.code.coding",
        "sliceName" : "loinc",
        "patternCoding" : {
          "system" : "http://loinc.org"
        },
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-extrakorporale-Verfahren-LOINC"
        }
      },
      {
        "id" : "Observation.code.coding:loinc.system",
        "path" : "Observation.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc.code",
        "path" : "Observation.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc.display",
        "path" : "Observation.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:IEEE-11073",
        "path" : "Observation.code.coding",
        "sliceName" : "IEEE-11073",
        "patternCoding" : {
          "system" : "urn:iso:std:iso:11073:10101"
        },
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/code-observation-extrakorporale-verfahren-iso11073"
        }
      },
      {
        "id" : "Observation.code.coding:IEEE-11073.system",
        "path" : "Observation.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:IEEE-11073.code",
        "path" : "Observation.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.subject",
        "path" : "Observation.subject",
        "min" : 1,
        "type" : [
          {
            "code" : "Reference",
            "profile" : [
              "https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
            ],
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "http://hl7.org/fhir/StructureDefinition/Device"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.encounter",
        "path" : "Observation.encounter",
        "type" : [
          {
            "code" : "Reference",
            "profile" : [
              "https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.effective[x]",
        "path" : "Observation.effective[x]",
        "type" : [
          {
            "code" : "dateTime"
          },
          {
            "code" : "Period"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.performer",
        "path" : "Observation.performer",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Practitioner",
              "http://hl7.org/fhir/StructureDefinition/PractitionerRole",
              "http://hl7.org/fhir/StructureDefinition/Organization",
              "http://hl7.org/fhir/StructureDefinition/CareTeam"
            ]
          }
        ]
      },
      {
        "id" : "Observation.value[x]",
        "path" : "Observation.value[x]",
        "min" : 1,
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "patternQuantity" : {
          "system" : "http://unitsofmeasure.org"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x].value",
        "path" : "Observation.value[x].value",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x].unit",
        "path" : "Observation.value[x].unit",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x].system",
        "path" : "Observation.value[x].system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x].code",
        "path" : "Observation.value[x].code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.bodySite",
        "path" : "Observation.bodySite",
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/BodySite-Observation-extrakorporale-Verfahren"
        }
      },
      {
        "id" : "Observation.device",
        "path" : "Observation.device",
        "type" : [
          {
            "code" : "Reference",
            "profile" : [
              "https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
            ],
            "targetProfile" : [
              "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/devicemetric-eingestellte-gemessene-parameter-extrakorporale-verfahren"
            ]
          }
        ],
        "mustSupport" : true
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.